Strany 2

10 ¾ Display resolutions up to 1280x1024 8-bit per pixel ¾ UMA (Unified Memory Architecture) LCD-TFT interface ¾ Also LCD-TFT flat panels c

Strany 3 - Table of Contents

11 Chapter 2 Jumper Description This chapter shows the jumpers layout and explains how to setup the jumpers. Jumper Layout and Configuration Fi

Strany 4

12 The following jumpers are located on the module: One 3-pin jumper (JP5) for which there are only two possibilities: ¾ Connecting pin 1 to

Strany 5

13 Chapter 3 Connectors Description This chapter provides a brief description of the SpacePC 1232 module’s connectors, with their positions and fu

Strany 6 - Chapter 1 Product Overview

14 Table below lists the name of the connectors with their function and the reference page. Table 2. Connector Functions Connector Funct

Strany 7 - (SMC FD37B782)

15 15 J1 and J2 for the ISA Bus The ISA BUS Connectors J1 and J2 carry the signals for the ISA Bus. These signals match definitions of the IEEE

Strany 8 - Product Definition

16 8. Press evenly the module onto the PC/104 stack. The picture below shows a typical module stack with 2 PC/104 modules, 1 PC/104 16-BIT m

Strany 9 - VGA interface

17 17 J3 for Multifunction & J14 for Mouse J3 is a double row 5 x 2 pin with 2.54-mm step connector and allows the connection of a speaker,

Strany 10 - LCD-TFT interface

18 Below is shown the connector pinout: Table 3. Multifunction connector Pin Signal Function 1 SPKR- Speaker output 2 SPKR+ Speaker output (

Strany 11

19 19 The audio output is based on two signals: one come from the output of Timer 2, and the other come from I/O port 61h compliant with the AT S

Strany 12

2 ABOUT THIS MANUAL This manual is meant for engineers and programmers who wish to use the Parvus SpacePC® 1232. It contains technical specificatio

Strany 13 - Connectors Layout

20 Parvus Multifunction Adapter Parvus Multifunction Adapter simplifies the connection of mouse and keyboard with two PS/2 connectors, pr

Strany 14

21 Table 6. J4 To CPU Multifunction Connector PIN # SIGNAL 1 SPKR 2-8 +5V 3 RES_PB_IN 4-10 N.C. 5 KBDAT 6 KBCLK 7 GND 9 BATT_IN

Strany 15 - J1 and J2 for the ISA Bus

22 J4 for PARALLEL or FDD A parallel port is available on connector J4 of the SpacePC 1232 module. This connector is a 13x2 pin with 2.54-mm st

Strany 16

23 23 14 GND Signal ground -- 20 GND Signal ground 14 15 PD6 Printer Data 6 out 8 MTR0# (*) Motor On 0 In/out 15 16 GND Signal grou

Strany 17 - Connector

24 To the Parallel PortTo the FDD Cable/ConnectorPower SupplyGND PIN1+5V PIN2Female Config. Male Config. Figure 10. Parvus Floppy Disk Drive

Strany 18

25 25 Serial 2Serial 1J6J5 Figure 12. J5 and J6 Connectors layout Both can be set as RS232 but only one (J5) can be set as RS422-485. Refer t

Strany 19 - PS/2 Mouse

26 - bit 0 of the MCR register = 0 means RS485 line receiving - bit 0 of the MCR register = 1 means RS485 line transmitting The I/O address

Strany 20 - Parvus Multifunction Adapter

27 27 Note. USB devices shouldn’t be directly connected to the J4 connector. Parvus USB/Audio CODEC Adapter can be used. In fact it provides for

Strany 21

28 15 SDATA_IN Serial DATA In This input receives audio serial data from the codec 16 GND Ground Signal 17 GND Ground Signal 18 NC Reserved

Strany 22 - Parallel

29 29 J1 USB1 J2 USB2 J3 Microphone IN J4 Line IN J5 Speaker OUT J6 Line OUT J7 CD IN J8 Aux IN J9 Video IN J10 Speakerphone IN/OUT J

Strany 23

3 Table of Contents Table of Contents ...

Strany 24 - +5V PIN2

30 IDE LedJP10 Figure 16. J9 and JP10 Connectors layout To install the hard disk, perform the following operations: ¾ Hardware installati

Strany 25 - Serial 1

31 31 J10 VGA Connector The J10 is a 5x2 pin connector with step =2.54 mm. J10VGA Figure 17. J10 Connector layout Refer to the following tabl

Strany 26 - J7 for 2 x USB

32 J11 Auxiliary Power Connector One auxiliary connector is available on the SpacePC 1232 module. J11 is a 6x2 pin connector with 2.54-mm step

Strany 27 - AC97 Audio

33 33 ATX Power Supply ¾ Connect pin 1 and pin 7 to the ground signal of the ATX Power Supply Unit. ¾ Connect pin 2 and pin 8 to the +5VDC sou

Strany 28 - Line OUT

34 Table 18. J13 Pin out Connector PIN SIGNAL 1 +VDD 2 N.C. 3 GND J18 for Ethernet The SpacePC 1232 module features a single-chip Fast Ethern

Strany 29 - J9 IDE Connector

35 35 It is shown below. RJ45 ConnectorTo CPU BoardEthernetConnector Figure 21. Parvus Ethernet Adapter The green led is fixed, and signals

Strany 30 - JP10 IDE LED Connector

36 J19 LCD-TFT Section LCD-TFT flat panels can be connected to J19 that is a double row 20 x 2 pin with 1.25-mm step connector. J19 Figure 2

Strany 31 - J10 VGA Connector

37 37 640x480 16bpp 64K colors 60 800x600 8bpp 256 colors 60 800x600 16bpp 64K colors 60 1024x768 8bpp 256 colors 60 1024x768 16b

Strany 33

39 Chapter 4 The Setup Program This chapter explains how to use and modify the setup options. These options allow configuring properly the CPU bo

Strany 34 - Ethernet

4 J19 LCD-TFT Section ... 36 Chapt

Strany 35 - To CPU Board

40 How to use the Setup program To enter in the Setup Program, reboot or switch-on your module and then press the “F2” key. After waiting a few

Strany 36 - J19 LCD-TFT Section

41 41 Press the “ESC” key to return to the items of the Main menu. Select “Quit” to exit from the Setup program. The follow screen will be di

Strany 37

42 General Page NOTE: The pictures below show the default configuration of the CPU Setup Program. In case of bad/wrong setup configuration

Strany 38

43 43 Date The date is displayed in standard format: MMM DD YYYY (month - day - year); all the three fields contain numerical values only. Flopp

Strany 39 - Chapter 4 The Setup Program

44 Option Description Note Disabled (*) No device selected (*) = Default setting Disk On Chip Solid-state memory device - size: 2 ... 144 MB

Strany 40 - How to use the Setup program

45 45  RTC time test Option Description Note Disabled (*) Normal BIOS test are used (*) = Default setting Enabled Reduce set of BIOS test ar

Strany 41 - The Setup pages

46 Floppy Controller This option enables or disables the on-board floppy disk controller. For example, if an external floppy disk contro

Strany 42 - General Page

47 47 1 MB 1 Megabyte reserved for Video Memory 2 MB 2 Megabyte reserved for Video Memory 4 MB (*) 4 Megabyte reserved for Video Memory (*) =

Strany 43 - Expansion Socket

48 0280h Audio emulator address selected at 280h Audio IRQ number Option Description Note None (*) No IRQ selected (*) = Default setting

Strany 44 - Quick Boot

49 49 Serial Ports 1 and 2 The number of serial ports is two. The Serial Port Mode is selectable (RS232, RS 422 and RS 485), like the IRQ numbe

Strany 45 - Devices Page

5 5 A.3 Safety Summary... 81 Ground t

Strany 46 - Video Memory

50 • Note(!): IRQ 11 can’t be used by peripherals connected to the ISA BUS if the printed circuit board code ends with the letter “S” (PC10011

Strany 47 - Network Adapter

51 51 None No IRQ selected 3 IRQ 3 selected 4 IRQ 4 selected 5 IRQ 5 selected 7 (*) IRQ 7 selected (*) = Default setting • Note: not a

Strany 48 - Communications Page

52 ATAPI unit type Option Description Note None (*) No unit selected Default setting for both ATAPI Units (Master1 & Slave1) (*) = Def

Strany 49 - Serial Ports 1 and 2

53 53 Translation Mode Modern hard-disks have more cylinders than maximum number of cylinders permitted by DOS, so, theoretically, a DOS machine

Strany 50 - Parallel Port

54 Detect Now Using the Detect Now option, the user can start manually the hard-disk autodetect procedure and see immediately the result, as we

Strany 51 - ATAPI Units Page

55 55 Option Description Note Ignore The floppy disks error is ignored Prompt User (*) When a floppy disks error occurs, the system stops and

Strany 53

57 Chapter 5 How to update the BIOS. The SSD This chapter explains how to use the BTOOL Program and gives information about the Integrated Solid

Strany 54 - Error Handling Page

58 How to update the BIOS: the BTOOL Program The BTOOL program is a utility used to program the BIOS (that is stored in the Flash EPROM) in t

Strany 55 - Power Management

59 59 OPTIONS EXPLANATION BTOOL /S This option runs the Setup program without the necessity of rebooting the system and then pressing “F2” B

Strany 56

6 Chapter 1 Product Overview The SpacePC 1232 is a highly integrated PC/104 CPU module, based on the AMD / National Semiconductor Geode GX1 MMX

Strany 57 - Solid State Disk

60 ¾ The program will store the new BIOS version. ¾ Follow all the instructions the BTOOL gives you ¾ BTOOL will inform you about the result

Strany 58

61 Chapter 6 Virtual Peripherals This chapter describes how to control the SpacePC 1232 module directly from a Laptop or a standard PC compatible c

Strany 59 - OPTIONS EXPLANATION

62 Local and redirected peripherals In “Virtual Peripherals” mode, two types of peripherals are used: ¾ The peripheral directly connected to t

Strany 60

63 63 CPU HOST COMPUTERVP adjustment (this end only)orRTSCTSDTRRI= short circuitShort ( ) for using VP mode with SERIAL1Short ( ) for using VP mo

Strany 61

64 10,12,14,16, 18,20,22,24 18..25 GND GND 18..25 (*) The “#” stands for: signal active low Pins not included in the table above are not co

Strany 62

65 65 If you select the [/V] [/K] [/D] [/C] parameters, the VP connection will be performed according to the following rules: ¾ Only the sele

Strany 63 - Parallel VP cable (*)

66 Chapter 7 Watchdog Timer This chapter describes the configuration of the Watchdog Timer with some examples. The watch dog is a part of the on–

Strany 64

67 67 Watchdog modalities The watchdog function resets the board at the end of the countdown. There are two ways to program the watchdog: • Usi

Strany 65 - Important note

68 MOV AL, 55h ; SPIO Configuration Mode Enable Key OUT DX, AL ; Enter in configuration mode ; Select Logical Device 8 (watch do

Strany 66 - Chapter 7 Watchdog Timer

69 69 Watchdog time-out pin For external control purposes, the status of the watchdog time-out event is provided to connector J11 pin 9. This sig

Strany 67 - Watchdog modalities

7 7 3.3V BusPCI NSGeode Gx1ProcessorNS Geode CS5530AI/O CompanionLCD-TFTVGA CRTHDD/DOMEthernet 10/100Parallel / Floppy D DRS232KeybPS/2 Mous

Strany 68 - Advance Information”

70 Chapter 8 Troubleshooting Many problems that you may encounter with operation of your SpacePC 1232 module are due to common errors like bad c

Strany 69 - Watchdog time-out pin

71 71 Common Problems and Solutions The following table lists some of the common problems that you may encounter while using your SpacePC 1232 m

Strany 70 - Chapter 8 Troubleshooting

72 below 4.75V when hard drive or floppy drive starts, add bypass caps Temperature too high Add fan, processor heat sink, or other cooling dev

Strany 71

73 73 ¾ Phone: 801-483-1533 ¾ Fax: 801-483-1523 If you have a sales question, please contact your local Parvus Sales Representative or the Regio

Strany 72 - Technical/Sales Assistance

74 Appendix A.1 Electrical and Environmental Specifications The following section provides tables and illustrations showing the electrical, mec

Strany 73 - Returning For Service

75 75 Note. In order to ensure proper operation and good reliability up to +60°C of ambient air temperature, the Geode GX1 chip and the Geode CS5

Strany 74 - Appendix

76 A.2 Mechanical Dimensions CPU Dimensions The SpacePC 1232 module’s mechanical dimensions are shown in the following picture: ¾ Dimensions:

Strany 75 - Power Consumption

77 77 Note: For further information about the mechanical dimensions of ISA and PCI buses please refer to the pc104 consortium site (www.pc104.org

Strany 76 - A.2 Mechanical Dimensions

78 Dimensions are in millimeters Figure 25. FDD Adapter Dimensions USB Audio CODEC Dimensions In the following picture are shown the USB Audi

Strany 77 - 3.0 12.7

79 79 USB Audio CODEC Dimensions Figure 26. USB Audio CODEC Dimensions Ethernet Adapter Dimensions In the following picture are shown the Eth

Strany 78 - USB Audio CODEC Dimensions

8 Product Definition SpacePC 1232 PC/104 CPU Module ¾ PC/AT compatible. ¾ PC/104 Form Factor: 3.550” x 3.775” (90 X 96 mm); height: 15 mm (0.6

Strany 79 - Ethernet Adapter Dimensions

80 Figure 27. Ethernet Adapter Dimensions Figure 28. Figure 29. Recommended Mounting Hole Locations for Ethernet Adapter Module Multif

Strany 80 - Dimensions are in inches

81 81 Figure 30. Multifunction Adapter Dimensions A.3 Safety Summary The following general safety precautions must be observed during all phas

Strany 81 - A.3 Safety Summary

82 Do Not Substitute Parts or Modify Equipment Because of the danger of introducing additional hazards, do not install substitute parts or pe

Strany 82

83 83 Any reference to a licensed program in this publication is not intended to state or imply that you can use only that licensed program. You

Strany 84

85 Acronyms and Abbreviations ACPI Advanced Configuration and Power Interface AGP Accelerated Graphic Port APM Advanced Power Management ATA AT A

Strany 85 - Acronyms and Abbreviations

86 For more information about this or other products in the Parvus line of embedded development tools and control systems call (801) 483-1533 from

Strany 86 - INTERFERENCE STATEMENT

87 87 For further information contact: Parvus® Corporation 3222 S. Washington St. Salt Lake City, Uta

Strany 87

9 9 ¾ Two cascaded 8259 interrupt controllers (15 interrupt channels) ¾ Three 8254 counter/timers (There are no extra timers) ¾ Three extra ti

Komentáře k této Příručce

Žádné komentáře