SMC Networks SMC7824M/FSW Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Síťové přepínače SMC Networks SMC7824M/FSW. SMC Networks SMC7824M/FSW User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 108
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
TigerAccess
10/100
Fast Ethernet Switch
24 100BASE-BX Single-Fiber Ports
2 10/100/1000BASE-T ports shared with SFP slots
2 module slots for Gigabit extender modules
Non-blocking switching architecture
Spanning Tree Protocol, RSTP and MSTP
Up to 12 LACP or static 8-port trunks
Layer 2/3/4 CoS support through eight priority queues
Layer 3/4 traffic priority with IP Precedence and IP DSCP
Full support for VLANs with GVRP and QinQ
IGMP multicast filtering and snooping
Support for jumbo frames up to 9 KB
Manageable via console, Web, SNMP/RMON
Security features: ACL, RADIUS, 802.1X
Installation Guide
SMC7824M/FSW
Zobrazit stránku 0
1 2 3 4 5 6 ... 107 108

Shrnutí obsahu

Strany 1 - TigerAccess

TigerAccess™ 10/100Fast Ethernet Switch◆ 24 100BASE-BX Single-Fiber Ports◆ 2 10/100/1000BASE-T ports shared with SFP slots◆ 2 module slots for Gigabit

Strany 2

COMPLIANCESxPower Cord SafetyPlease read the following safety information carefully before installing the switch:War ning: Installation and removal of

Strany 3 - Installation Guide

GLOSSARYGlossary-4LEDLight emitting diode used for monitoring a device or network condition.Local Area Network (LAN) A group of interconnected compute

Strany 4 - Trademarks:

GLOSSARYGlossary-5TIATelecommunications Industry AssociationTransmission Control Protocol/Internet Protocol (TCP/IP)Protocol suite that includes TCP a

Strany 5

GLOSSARYGlossary-6

Strany 6

Index-1Numerics10 Mbps connectivity rules 4-8100 Mbps connectivity rules 4-81000 Mbps connectivity rules 4-61000BASE combo module 1-101000BASE-LX fibe

Strany 7 - COMPLIANCES

INDEXIndex-2switch 1-11fiber cables 4-4duplex fiber 4-4multimode 4-4simplex fiber 4-4single mode 4-4fiber-to-the-home, introduction to 2-1IIEEE 802.3

Strany 8 - Safety (EEC)

INDEXIndex-3problems, troubleshooting A-1RRJ-45 port 1-4connections 4-1pinouts B-5rubber foot pads, attaching 3-6SSC port connections 4-4screws for ra

Strany 11 - OMPLIANCES

38 TeslaIrvine, CA 92618Phone: (949) 679-8000FOR TECHNICAL SUPPORT, CALL:From U.S.A. and Canada (24 hours a day, 7 days a week)(800) SMC-4-YOU; (949)

Strany 12 - PSE Alarm

COMPLIANCESxiVeuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch:AVERTISSEMENT: L’installation et la dépo

Strany 13 - War nings (in German)

COMPLIANCESxiiBitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen:WARNUNG: Die Installation und der Ausbau d

Strany 14

COMPLIANCESxiiiWarnings and Cautionary MessagesWar nings (in German)Warning: This product does not contain any serviceable user parts.Warning: Install

Strany 15

COMPLIANCESxivEnvironmental StatementThe manufacturer of this product endeavours to sustain an environmentally-friendly policy throughout the entire p

Strany 16

xvTABLE OF CONTENTS1 About the TigerAccess Switch . . . . . . . . . . . . . . . . . . . 1-1Overview . . . . . . . . . . . . . . . . . . . . . . .

Strany 17 - APPENDICES:

TABLE OF CONTENTSxviEquipment Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3Package Contents . . . .

Strany 18

TABLE OF CONTENTSxviiAPPENDICES:A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1Diagnosing Switch Indicators . . .

Strany 19

TABLE OF CONTENTSxviiiE Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . .E-1GlossaryIndex

Strany 20

xixTABLESTable 1-1 Optional SFP Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5Table 1-2 Port and System Status LEDs . . . .

Strany 22 - MgmtMgmt

xxFIGURESFigure 1-1 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2Figure 1-2 Port and System LEDs . . . .

Strany 23 - Description of Hardware

1-1CHAPTER 1 ABOUT THE TIGERACCESS SWITCHOverviewThis device is an intelligent Layer 2 switch designed for delivering Fiber-To-The-Home (FTTH) high-sp

Strany 24

ABOUT THE TIGERACCESS SWITCH1-2This switch can enhance your network with full support for Spanning Tree Protocol, private VLAN port isolation, and ban

Strany 25 - 1000BASE-ZX (SMCBGZLCX1)

DESCRIPTION OF HARDWARE1-3Network Management OptionsThis switch contains a comprehensive array of LEDs for “at-a-glance” monitoring of network and por

Strany 26

ABOUT THE TIGERACCESS SWITCH1-4100BASE-TX and 1000BASE-T PortsThe switch contains 24 100BASE-TX RJ-45 ports that operate at 10/100 Mbps, half or full

Strany 27

DESCRIPTION OF HARDWARE1-5SFP SlotsThe Small Form Factor Pluggable (SFP) transceiver slots are shared with RJ-45 ports (ports 25~26 on the front panel

Strany 28 - Figure 1-3 Fan Tray

ABOUT THE TIGERACCESS SWITCH1-6Port and System Status LEDsThis switch includes a display panel for key system and port indications that simplifies ins

Strany 29 - Power Modules

DESCRIPTION OF HARDWARE1-7Table 1-2 Port and System Status LEDs LED Condition StatusMajor Red Indicates presence within the system of one or more maj

Strany 30

ABOUT THE TIGERACCESS SWITCH1-8Fan TrayA removable fan tray on the right side of the front panel contains three fans that provide cooling for the chas

Strany 31 - Features and Benefits

DESCRIPTION OF HARDWARE1-9Power ModulesThis switch provides two power module options: -48 VDC and universal AC. For specifications on the power conver

Strany 32

38 TeslaIrvine, CA 92618Phone: (949) 679-8000TigerAccess™ 10/100Installation GuideFrom SMC’s Tiger line of feature-rich workgroup LAN solutionsJanuary

Strany 33 - Fiber-To-The-Home (FTTH)

ABOUT THE TIGERACCESS SWITCH1-10Optional Media Extender Module1000BASE Combo ModuleFigure 1-5 Single-Port 1000BASE-T/SFP Combo ModuleThe 1000BASE-T R

Strany 34 - Connection Examples

FEATURES AND BENEFITS1-11Features and BenefitsConnectivity• 24 100BASE-BX full-duplex single-fiber for downlink connections to subscribers.• 2 1000BAS

Strany 35 - Downlink Fiber Connections

ABOUT THE TIGERACCESS SWITCH1-12• Switching table with a total of 16K MAC address entries and 1K static addresses.• Provides store-and-forward switchi

Strany 36 - Uplink Connections

2-1CHAPTER 2 NETWORK PLANNINGFiber-To-The-Home (FTTH)Fiber-To-The-Home (FTTH) has always been an attractive option for Internet access. It has all the

Strany 37 - Management Connections

NETWORK PLANNING2-2cable. Depending on the service provider’s offerings, a CPE may also include VoIP POTS ports for VoIP connections over standard pho

Strany 38 - Private VLAN Connections

CONNECTION EXAMPLES2-3Downlink Fiber ConnectionsFiber optic technology allows for longer cabling than any other media type. A 100BASE-BX single-mode f

Strany 39 - Application Notes

NETWORK PLANNING2-4Uplink ConnectionsThe switch provides 24 downlink fiber ports, two combo RJ-45/SFP uplink ports built into the switch, and two slot

Strany 40

CONNECTION EXAMPLES2-5Management ConnectionsThis switch can be managed over built-in RJ-45 Ports 27-28, Ports 25-26 when optional 1000BASE-T/SFP uplin

Strany 41 - Selecting a Site

NETWORK PLANNING2-6Private VLAN ConnectionsThis switch can be configured for up to 255 VLANs. Also, it supports Private VLANs that allow traffic isola

Strany 42 - Ethernet Cabling

APPLICATION NOTES2-7Application Notes1. Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstatio

Strany 43 - Equipment Checklist

Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, n

Strany 44 - Mounting

NETWORK PLANNING2-8

Strany 45 - Desktop or Shelf Mounting

3-1CHAPTER 3 INSTALLING THE SWITCHSelecting a SiteTigerAccess 10/100 units can be mounted in a standard 19-inch equipment rack or on a flat surface. B

Strany 46 - NSTALLING

INSTALLING THE SWITCH3-2is recommended. This switch provides two power module options: -48 VDC and universal AC. Verify that the external power requi

Strany 47

EQUIPMENT CHECKLIST3-3Equipment ChecklistAfter unpacking the TigerAccess 10/100 unit, check the contents to be sure you have received all the componen

Strany 48

INSTALLING THE SWITCH3-4MountingA TigerAccess 10/100 unit can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instr

Strany 49 - Grounding the Chassis

MOUNTING3-52. Mount the device in the rack, using four rack-mounting screws (not provided).Figure 3-3 Installing the Switch in a Rack3. If installing

Strany 50 - Connecting to a Power Source

INSTALLING THE SWITCH3-6Figure 3-4 Attaching the Adhesive Feet2. Set the device on a flat surface near an external power source, making sure there ar

Strany 51 - ONNECTING

INSTALLING AN OPTIONAL MODULE INTO THE SWITCH3-7Installing an Optional Module into the SwitchFigure 3-5 Installing an Optional ModuleNote: The slide-

Strany 52 - Return/24VDC B)(Source

INSTALLING THE SWITCH3-85. If you are sure the module is properly mated with the connector, tighten the retainer screws to secure the module in the sl

Strany 53

GROUNDING THE CHASSIS3-9Notes: 1. SFP transceivers are hot-swappable. The switch does not need to be powered off before installing or removing a trans

Strany 54 - Wiring Map for Serial Cable

vLIMITED WARRANTYLimited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, un

Strany 55 - Connecting to the Alarm Port

INSTALLING THE SWITCH3-10Connecting to a Power SourceThis switch supports both AC and DC power conversion modules.Connecting DC PowerWhen a -48 VDC po

Strany 56 - Wiring Map for Alarm Cable

CONNECTING TO A POWER SOURCE3-11To connect the switch to a power source:1. First verify that the external DC power supply can provide -36 to -72 VDC,

Strany 57

INSTALLING THE SWITCH3-12Figure 3-7 DC Plug Connections7. Push each wire about half an inch into the opening on the plug, and tighten down the clamp

Strany 58

CONNECTING TO A POWER SOURCE3-13Connecting AC PowerWhen a universal AC power module is installed in the switch, external AC power must be supplied to

Strany 59 - Twisted-Pair Devices

INSTALLING THE SWITCH3-145. If you have installed both a primary and redundant power conversion modules, verify that the LEDs on both modules are lit

Strany 60 - ONNECTIONS

CONNECTING TO THE ALARM PORT3-15The serial port’s configuration requirements are as follows:• Default Baud rate—9,600 bps• Character Size—8 Characters

Strany 61 - Network Wiring Connections

INSTALLING THE SWITCH3-16Wiring Map for Alarm CableThe signals include relay contacts for major and minor system alarms, and external alarm inputs.Tab

Strany 62 - Fiber Optic Devices

CONNECTING TO THE ALARM PORT3-17The following figure shows the pinout information for the DB-15 ALARM connector on the front panel.Figure 3-11 Extern

Strany 63

INSTALLING THE SWITCH3-18

Strany 64 - Connectivity Rules

4-1CHAPTER 4 MAKING NETWORK CONNECTIONSConnecting Network DevicesThis TigerAccess 10/100 switch is designed to interconnect multiple segments (or coll

Strany 65 - ONNECTIVITY

viWARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN

Strany 66

MAKING NETWORK CONNECTIONS4-2Caution: Do not plug a phone jack connector into an RJ-45 port. This will damage the switch. Use only twisted-pair cables

Strany 67 - ONNECTION

TWISTED-PAIR DEVICES4-3Network Wiring ConnectionsToday, the punch-down block is an integral part of many of the newer equipment racks. It is actually

Strany 68

MAKING NETWORK CONNECTIONS4-4Fiber Optic DevicesEach of the 100BASE-BX SC connectors on the switch’s front panel connects directly to a CPE at the sub

Strany 69 - ROUBLESHOOTING

FIBER OPTIC DEVICES4-51. Remove and keep the fiber port’s rubber cover. When not connected to a fiber cable, the rubber cover should be replaced to pr

Strany 70

MAKING NETWORK CONNECTIONS4-64. As a connection is made, check the Link LED on the switch corresponding to the port to be sure that the connection is

Strany 71 - In-Band Access

CONNECTIVITY RULES4-71000 Mbps Gigabit Ethernet Cable LengthsTable 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable LengthCable Type Maximum Cable Lengt

Strany 72

MAKING NETWORK CONNECTIONS4-8100 Mbps Fast Ethernet Cable Lengths10 Mbps Ethernet Cable LengthsTable 4-5 Maximum Fast Ethernet Cable LengthType Cable

Strany 73

CABLE LABELING AND CONNECTION RECORDS4-9Cable Labeling and Connection RecordsWhen planning a network installation, it is essential to label the opposi

Strany 74

MAKING NETWORK CONNECTIONS4-10

Strany 75

A-1APPENDIX ATROUBLESHOOTINGDiagnosing Switch IndicatorsThis switch can be easily monitored through panel indicators to identify problems. The table b

Strany 76 - Crossover Wiring

viiCOMPLIANCESFCC - Class AThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the

Strany 77

TROUBLESHOOTINGA-2Link LED is Off Network cable or Ethernet device attached to this port may be defective.• Verify that the switch and attached device

Strany 78 - 1000BASE-T Cable Requirements

POWER AND COOLING PROBLEMSA-3Power and Cooling ProblemsIf the power indicator does not turn on when the power cord is plugged in, you may have a probl

Strany 80

B-1APPENDIX BCABLESTwisted-Pair Cable and Pin AssignmentsFor 10/100BASE-TX connections, the twisted-pair cable must have two pairs of wires. For 1000B

Strany 81 - Physical Characteristics

CABLESB-210BASE-T/100BASE-TX Pin AssignmentsUse unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Cate

Strany 82 - HARACTERISTICS

TWISTED-PAIR CABLE AND PIN ASSIGNMENTSB-3Straight-Through WiringIf the twisted-pair cable is to join two ports and only one of the ports has an intern

Strany 83 - Management Features

CABLESB-4Crossover WiringIf the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (MDI-X) or neither port is label

Strany 84 - Compliances

TWISTED-PAIR CABLE AND PIN ASSIGNMENTSB-51000BASE-T Pin AssignmentsAll 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use straight

Strany 85 - Extender Modules

CABLESB-61000BASE-T Cable RequirementsAll Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing th

Strany 86

FIBER STANDARDSB-7Fiber StandardsThe current TIA (Telecommunications Industry Association) 568-A specification on optical fiber cabling consists of on

Strany 87 - GERMAN INSTRUCTIONS

COMPLIANCESviiiCE Mark Declaration of Conformance for EMI and Safety (EEC)SMC contact for these products in Europe is:SMC Networks Europe,Edificio Con

Strany 89 - (Grounding the Chassis)

C-1APPENDIX C SPECIFICATIONSPhysical CharacteristicsPorts24 100BASE-BX single-fiber subscriber ports (SC)2 Gigabit Ethernet combination uplink ports (

Strany 90 - Anschluss an eine Stromquelle

PHYSICAL CHARACTERISTICSC-2Aggregate Bandwidth12.8 GbpsSwitching Database8K MAC address entries, 1K static MAC addresses; 64 multicast groupsLEDsSyste

Strany 91

SPECIFICATIONSC-3Maximum Current1.20 A @ -38 VDC (with two expansion modules)0.60 A @ -75 VDC (with two expansion modules)0.59 A @ 110 VAC (with two e

Strany 92 - Zurück Quelle/24VDC B)(

STANDARDSC-4StandardsIEEE 802.3-2005 Ethernet, Fast Ethernet, Gigabit EthernetLink Aggregation Control Protocol (LACP)Full-duplex flow control (ISO/IE

Strany 93

SPECIFICATIONSC-5SafetyCSA/CUS (CSA 22.2. NO 60950-1 & UL60950-1)TÜV/GS (EN60950-1) CB (IEC60950-1)Extender ModulesGigabit Extender Module (RJ-45/

Strany 94 - NSTRUCTIONS

EXTENDER MODULESC-6

Strany 95 - NFORMATION

D-1APPENDIX DGERMAN INSTRUCTIONSEine Site Auswählen (Selecting a Site)Die Schalter können in ein Standard-19-Zoll-Ausrüstungsgestell oder auf eine fla

Strany 96

GERMAN INSTRUCTIONSD-2• Sicherstellen, dass das Gerat an eine separate Stromquelle mit Erdanschlus mit einer Netzspannung von 100 bis 240 V AC (Wechs

Strany 97 - Glossary-1

DAS ERDEN DES GEHÄUSES (GROUNDING THE CHASSIS)D-3So montieren Sie Geräte an ein Rack:1. Befestigen Sie die Metallwinkel mit den im Metallwinkel-Montag

Strany 98 - Glossary-2

COMPLIANCESixAustralia AS/NZS 3548 (1995) - Class ASMC contact for products in Australia is:SMC Communications Pty. Ltd.Suite 18, 12 Tryon Road, Lindf

Strany 99 - Glossary-3

GERMAN INSTRUCTIONSD-45. Dann schließen Sie das Erdungskabel an den Erdungspunkt des Racks an.Vorsicht: Die Erdungsverbindungen dürfen nicht entfernt

Strany 100 - Glossary-4

ANSCHLUSS AN EINE STROMQUELLE (CONNECTING TO A POWER SOURCE)D-5Plug Connections” auf Seite 3-8 beschrieben sind, erfüllt sind. Die Drähte sollten auch

Strany 101 - Glossary-5

GERMAN INSTRUCTIONSD-6RETA/B (Return) Leitungen für die Stromquellen A bzw. Bbenutzt. Benutzen Sie einen Flachkopfschraubendreher, um die Schrauben de

Strany 102 - Glossary-6

ANSCHLUSS AN EINE STROMQUELLE (CONNECTING TO A POWER SOURCE)D-7Stromschalter auf der Vorderseite des Stromwandlungsmodule auf AN (mit “–” markiert). 1

Strany 103

GERMAN INSTRUCTIONSD-8Figure D-2 Wechselstromanschluss4. Wenn der Switch angeschaltet ist, überprüfen Sie die Anzeigen des Strommoduls, um sicherzuge

Strany 104

E-1APPENDIX EORDERING INFORMATIONTable E-1 TigerAccess 10/100 Products and AccessoriesProduct Number DescriptionSMC7824M/FSW 24-Port Fast Ethernet Sw

Strany 105

ORDERING INFORMATIONE-2

Strany 106

Glossary-1GLOSSARY10BASE-TIEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5 UTP cable.100BASE-BXIEEE 802.3-2005 spec

Strany 107

GLOSSARYGlossary-2Auto-NegotiationSignalling method allowing each node to select its optimum operational mode (e.g., speed and duplex mode) based on t

Strany 108

GLOSSARYGlossary-3Fast EthernetA 100 Mbps network communication system based on Ethernet and the CSMA/CD access method.Full DuplexTransmission method

Komentáře k této Příručce